Instruction Manual ME3816-6C

Installation Environment

Avoid the following locations for installation.
  • Where the unit receives radiant heat from strong heat sources such as heat treatment furnaces
  • Where the ambient temperature exceeds the range of 0 to 40°C
  • Where the temperature changes rapidly and condensation occurs
  • Where the relative humidity exceeds 85% RH
  • Where the unit receives direct sunlight
  • Where the unit is exposed to corrosive or combustible gases
  • Where the ambient air contains a large amount of dust, salt or iron (at levels exceeding those typical of an assembly plant)
  • Where the unit is subject to splashed water or oil (including oil mist or cutting fluid) or chemical solutions
  • Where the body receives impact or vibration
  • Where the altitude is more than 1,000 m
Provide sufficient work space for the following maintenance and inspection:
If the unit is used in any of the following locations, provide sufficient shielding measures:
  • Where noise is generated due to static electricity, etc.
  • Where the unit is subject to a strong electric or magnetic field
  • Where the unit is subject to ultraviolet or radiation