Inrush Current
The in-rush current of the motor drive DC power supply (PSA-200) is as stated below.
Item | Internal temperature | Inrush current |
|---|---|---|
Motor power | 40°C | 50A |
55°C | 70A | |
Control power | 40°C | 40A |
55°C | 60A |
Note 1 Inrush current should flow for approximately 20ms after the power is turned on. Be aware that the inrush current could vary depending on the impedance and the internal element temperature (thermistor) in the power supply line.