Instruction manual ME3816-6B

Order to Turn Power On

Shown below is the recommended order to turn the power on. There should be no problem even if the order is swapped.
◆For Models with Pulse Motor Equipped and 24V AC Servomotor Equipped Model
[Order to turn power on]
  1. Turn ON the power to the peripheral devices such as PLC.
  2. Turn ON the control power supply (24V DC) to ELECYLINDER units.
[Time before turning ON power supply after turning it OFF]
  • ELECYLINDER Unit : 1s or more after turning 24V DC power supply OFF
[Time required for ELECYLINDER startup (Power supply to initialization)]
Approx. 1s
◆For Models with 200V AC Servomotor Equipped
[Order to turn power on]
  1. Turn ON the power to the peripheral devices such as PLC.
  2. Turn ON the control power supply (24V DC) to ELECYLINDER units.
  3. Turn on the DC power supply (PSA-200) for motor drive.
    After supplying the control power (L1C-L2C), supply the motor driver power (L1-L2).
    Or, turn both of them at the same time.
[Time before turning ON power supply after turning it OFF]
  • ELECYLINDER Unit: 1s or more after turning 24V DC power supply OFF
  • DC power supply (PSA-200) for motor drive: 2s or more after turning 24V DC power supply OFF
[Time required for ELECYLINDER startup (Power supply to initialization)]
Approx. 3s