Warnings in DC Power Supply for Motor Drive (PSA-200)
The DC power supply for motor drive (PSA-200) has generated a warning.
No. | Content | Causes and countermeasures | Countermeasure |
|---|---|---|---|
1 | Internal relay life count warning | Open/close count of the internal relay has reached the end of the life. | Replace the DC power supply for motor drive. |
2 | Electrolytic capacitor life warning | The electrolytic capacitor has reached the end of its life. | The warning being generated is not stating there is no capacity in the capacitor (dry-up), however, it is recommended to have the DC power supply for motor drive replaced as early as possible. |
3 | Fan revolution drop warning | The fan revolution count has dropped below the threshold. | The warning being generated is not stating the fan revolution count has stopped, however, it is recommended to have the fan unit replaced as early as possible. |