Alarm Group B: Motor Abnormality Alarm
Motor abnormality occurred.
No. | Cause | Countermeasure |
|---|---|---|
1 | The internal temperature of the motor may be too high. | Improve the surrounding environment of the motor so that the ambient temperature is 40°C or less. If the abnormality is resolved upon turning the power back on after the ambient temperature is lowered, the internal temperature may have been excessive. [Countermeasure examples] Remove the heat source/turn OFF the heat source/install a fan/install a temperature shield/improve thermal conductivity of the base/install a heat dissipation fin, etc. |
2 | The ELECYLINDER may be being used under conditions exceeding the specifications. | Check the specification values such as payload, acceleration/deceleration and speed, and adjust them appropriately. |
3 | If this alarm recurs after performing the inspection above and improving the power supply environment, it is highly likely that the motor has failed. | Replace the motor unit. For details, refer to the Instruction manual for each ELECYLINDER, Maintenance and Inspection. |