Maintenance Warning 3: Overload Warning Level
This is an alert that the target value of the "overload warning level" set by the customer has been reached.
No. | Content | Causes and countermeasures |
|---|---|---|
1 | Before the ELECYLINDER stops operation due to the "overload alarm", follow the troubleshooting procedure and conduct visual inspection and maintenance. * To disable this warning, change the "overload warning level" in "Maintenance Information" to 100%. | [Causes] The warning may be caused by the depletion of grease on the sliding screw/guide inside the ELECYLINDER, brake failure, motor failure, contact with peripheral equipment, etc. |
[Countermeasure 1] Visually check for the depletion of grease on the sliding screw/guide inside the ELECYLINDER, intrusion of foreign matter, etc. If this is the case, clean the inside of the ELECYLINDER and replenish the grease. For details, refer to the instruction manual for each ELECYLINDER, "Cleaning" or "Greasing method". | ||
[Countermeasure 2] Check the sliding movement of the ELECYLINDER body. If there is no abnormality in the sliding motion, there is a possibility of motor or brake failure. Replacement of the motor unit is recommended. For details, refer to the instruction manual for each ELECYLINDER, "Maintenance and Inspection". |
* For setting, refer to Maintenance Information or Setting Maintenance Information.