Instruction manual ME3816-6B

Preventive and Predictive Maintenance

The ELECYLINDER has a predictive maintenance function that notifies the user with an "overload warning" when the load exceeds normal status.
It also has a preventive maintenance function that prompts the user to perform maintenance if the travel count or the travel distance exceeds the set values.
image
Preventative maintenance
Predictive maintenance
Travel distance [km/m]
(Count of back and forth between 0 and 180 deg. (To be figured out from total distance) [times])
Overload warning
Travel count [times]
If the criteria are set in advance, the LED built into the body will flash green/red to notify that the maintenance period is up.
Preventative maintenance
Predictive maintenance
  • Regular maintenance that is performed based on a reference period regardless of whether or not there are equipment breakdowns.
  • Prevents unexpected breakdowns.
  • Extends service life.
  • Maintenance that is performed when, based on regular equipment monitoring, an abnormality is predicted to occur.
  • Predicts unexpected breakdowns.
  • Prevents sudden line stoppages.