Order to Turn Power Off
Shown below is the recommended order to turn the power off. There should be no problem even if the order is swapped.
◆For Models with Pulse Motor Equipped and 24V AC Servomotor Equipped Model
[Order to turn power off]
[Order to turn power off]
- Turn OFF the control power supply (24V DC) to ELECYLINDER units.
- Turn OFF the power to the peripheral devices such as PLC.
◆For Models with 200V AC Servomotor Equipped
[Order to turn power off]
[Order to turn power off]
- Turn OFF the motor drive DC power supply (PSA-200).
Turn the motor drive power (L1-L2) off first, and then turn the control power (L1C-L2C) off.
Or, turn them off at the same time. - Turn OFF the control power supply (24V DC) to ELECYLINDER units.
- Turn OFF the power to the peripheral devices such as PLC.